It must be a bug, I can reproduce the error here, it happens with 5.09, and it does not happen with 5.08. There is one zero sample in the middle of the center lobe, not all the time, but it appears every 3 seconds or so in a continuous tone. It is easy to just listen for the error as it is quite audible. Oeyvind 2008/11/5 Carlos Pita : > Hi again, > > sorry for buzzing like this but I'm having a bad headache with buzz > and friends (again, with 5.09). > > I discovered that for kr != sr, even when kr is as high as sr/2, some > abrupt signal changes to zero occur at the peak of the main lobes from > time to time, introducing audible artifacts. I'm using very large > tables (65536 samples) and sr is 48000. I've attached a short sound > that illustrates the issue (look at it with reasonable zoom, it's too > short to be heard). > > Is this expected or is it a bug? > > The instrument in question is: > > > > > > > > > sr = 48000 > kr = 24000 > nchnls = 2 > > instr 1 > > idur = p3 > iamp = p4 > ifrq = p5 > > asig1 buzz iamp, ifrq, 10, 2 > > outs asig1,asig1 > > endin > > > > > > > f 2 0 65536 10 1 > > i1 0 30 10000 100 10 > > > > > > > Regards > -Carlos > > Send bugs reports to this list. > To unsubscribe, send email sympa@lists.bath.ac.uk with body "unsubscribe csound"